Skip to content
Black in time Prices until 16/11, 12:00 until 16/11, 12:00 2d 21h 52m

Control Box Joyonway P23B32

Complete guide to the Joyonway P23B32 Control Box

1 Introduction

This section provides essential information for the end user. For technical details and installation procedures, refer to the Technical Sheet at the bottom of the document.

2 What is the P23B32 Control Box

The P23B32 is a compact Joyonway electronic control box for hot tubs, with the unique advantage of supporting 400V three-phase power supply in addition to 220-240V. It is ideal for installations where the main line is three-phase 400V. It manages up to 3 pumps, heating, filtration, blower, lights and ozone system.

3 Electrical Connection

The electrical installation of the control box must be performed exclusively by a qualified electrician, in compliance with CEI 64-8 standards and D.M. 37/2008.

System Requirements - Single Phase 220V

RequirementSpecification
Voltage220-240V~ 50/60Hz
Residual current deviceDedicated 30mA
Circuit breaker32A curve C
Cable section3G4mm² (phase + neutral + ground)
GroundingMandatory

System Requirements - Three Phase 400V

RequirementSpecification
Voltage400V 3N~ 50/60Hz
Residual current deviceDedicated 30mA four-pole
Circuit breaker16A four-pole curve C
Cable section5G2.5mm² (3 phases + neutral + ground)
GroundingMandatory

DANGER: Do not attempt to make electrical connections yourself. 400V voltage is particularly dangerous. Incorrect connection can cause electrocution, fire or irreparable damage to the control box.

Power Supply Type

The P23B32 is the only Joyonway model that supports both 220-240V and 400V three-phase. This flexibility makes it ideal for industrial installations or where the main system is three-phase 400V.

ConfigurationVoltageCurrentRecommended Use
Single phase220-240V~1x32AStandard domestic installations
Two phase220-240V~2x16ALoads distributed over 2 phases
Three phase 400V400V 3N~16AIndustrial systems, native three-phase

IMPORTANT: Unlike other models, the P23B32 can be connected directly to a 400V three-phase line without transformers. Check the jumper configuration before connection.

3.1 Standard P23B32 Connection (single phase 220-240V + ground)

Schema p23b32 220v

 

Warning: this is the standard configuration and no jumper modifications are required during installation.

3.2 Three Phase 400V Connection

Schema p23b32 380v

For 400V three-phase connection, modify the jumpers as indicated in the following table BEFORE connecting power.

3.3 Jumper Configuration for Power Supply

Electrical configuration is done via jumpers PJ1, PJ2, PJ3 on the board. CONFIGURE BEFORE CONNECTING POWER.

ConfigurationVoltageCurrentPJ1PJ2PJ3
Single phase220-240V~ 50/60Hz1x32AJ8-J9J4-J6J3-J5
Three phase 400V400V 3N~ 50/60Hz16AJ8-J9J4-J7-

WARNING: Configure jumpers BEFORE connecting power. Incorrect configuration, especially at 400V, can cause serious and irreparable damage to the control box and connected components.

Post-Installation Check

After installation by the technician, verify that:

  1. The status LED on the control box is on
  2. The panel display turns on and shows the temperature
  3. No error codes appear
  4. The pumps respond to panel commands
  5. The heater activates when requested

4 Controlled Functions

The P23B32 control box manages the following components:

ComponentFunction
Pump 1Main pump (1 or 2 speed)
Pump 2Secondary pump
Pump 3 / BlowerAdditional pump OR Blower (configurable)
Circulation PumpContinuous filtration and circulation
HeaterWater heating
OzoneOzone sanitization system
Light12V LED lighting (max 15W)

NOTE: Output CN5 can be configured as Blower OR as Pump3 via DIP switch A3. It is not possible to have both simultaneously.

5 Compatible Panels

The P23B32 works with the Joyonway control panel:

PanelTypeNotes
PB553LCD with buttonsStandard Joyonway panel

6 Advanced Technical Information

This section is intended for qualified installers and technicians.

6.1 Product Identification

SpecificationValue
ModelP23B32 Control System
VersionV1.0
CertificationsCE
TargetCompact systems with 400V support

6.2 Electrical Specifications

ParameterValue
Single Phase Power220-240VAC, 50/60Hz
Three Phase Power400V 3N~, 50/60Hz
Single Phase Configuration1x32A
Three Phase 400V Configuration16A
Frequency50/60Hz

6.3 System Outputs

ConnectorDeviceMax Current
CN1PUMP1 (1 or 2 SPD)10A or HIGH:10A/LOW:2.5A
CN2PUMP210A MAX
CN5BLOWER or PUMP310A MAX
CN6CIRC PUMP2.5A MAX
CN7OZONE1A MAX
CN22LIGHT12VDC, 15W MAX
CN10AUX POWER1A MAX

6.4 DIP Switch S1 (A1-A5)

SwitchONOFF
A1HOST SYSTEMSLAVE SYSTEM
A2POWER NOT LIMITPOWER LIMIT
A3BLOWER OUTPUT (CN5)PUMP3 OUTPUT (CN5)
A4SETTINGSTORE SETTING
A5PUMP1 1-SPEEDPUMP1 2-SPEED

NOTE: DIP A3 determines whether CN5 works as Blower or as Pump3. DIP A5 determines whether Pump1 is 1 or 2 speed.

6.5 Fuses

FuseValue
F1500V~/30A
F2500V~/30A
F3250V~/T10A

6.6 Load Configuration Procedure

  1. Set DIP switch A4 to ON
  2. Turn on the system
  3. Enter the Set menu on the panel
  4. Press "-" or "S" for 3 seconds to access Function
  5. Configure the loads (Jets 1-3, Light, Blower, Ozone)
  6. Return to Set within 60 seconds to save
  7. Turn off and set A4 to OFF

6.7 Supported Light Types

TypeWiring
4 wire RGBB (Blue), G (Green), R (Red), +12V
2 wireGND, +12V
  • Installations with native three-phase 400V system
  • Compact hot tubs (2-3 pumps)
  • Situations requiring Blower/Pump3 flexibility
  • International installations (50/60Hz support)

Manuals and technical sheets

Can’t find the problem?

  • PB553 Display
    Joyonway Control Systems

    PB553 Display

    Complete guide to Joyonway PB553 control panel.

Accessibility Statement

The service

This is the online shop of Beauty Luxury, where you can browse products, request a quotation, and place an order.

Applicable requirements

The service is provided by Beauty Luxury S.r.l. and is an e-commerce service. It is subject to the accessibility requirements of Annex I, Sections III and IV, point (f), of Directive (EU) 2019/882, transposed into Italian law by Legislative Decree No. 82 of 27 May 2022. The sections below describe how the service meets those requirements.

How the site works

Every page can be used with a keyboard alone. The first link on each page skips to the main content. The element you are on is always outlined, and menus, drawers, and dialogues return you to the control that opened them when they close.

Display settings, linked at the top of every page and in the footer, change text size, text spacing, link underlining, and contrast; your choice is stored only in your browser.

Accessibility features

Perceivable

  • Contrast (minimum): Where text sits on a solid background, it stands out clearly enough to be read with reduced vision, at the levelWCAGrequires. Where text sits on a photograph, the high-contrast and plain views in the display settings give it a solid background.
  • Resize text: Text can be resized up to 200 per cent without loss of content or functionality.
  • Text spacing: Line, word, and letter spacing can be increased without loss of content or functionality.
  • Images and colour: Images that carry meaning have a text alternative, and colour is never the only way information is given.

Operable

Every function can be reached and used with a keyboard, focus follows the reading order and stays visible, nothing flashes, and moving content can be paused.

Understandable

Every page declares its language, navigation and controls stay consistent from page to page, and form fields have visible labels with errors described in words.

Robust

Interactive components expose their name, role, and state to assistive technologies.

Buying and paying

Account creation, sign-in, quotation requests, checkout, and payment meet the points above.

Product information

Where a manufacturer provides accessibility information about a product, we publish it on the product page.

Customer support

Customer service provides information about the accessibility of the service and its compatibility with assistive technologies by telephone (+39 0541 648566), by email (info@beauty-luxury.com), andby chat.

Privacy

We do not use tracking techniques that could infer a user's disability.

How conformity is maintained

We test the site againstWCAG2.1 Level AA, using clause 9 ofEN 301 549V3.2.1. We run automated checks whenever templates, components, stylesheets, or checkout change, and review the site manually at regular intervals.

This statement read aloud

Use the read-aloud button on this page to have this statement read to you.